1. Introduction:
BC-9600 type (deft type in mixed type) to be automatic water sampler is my company launched used for surface water and wastewater sampling, for water monitoring, carry out investigation and the total amount control pollution sources for environmental monitoring instruments. It USES common international peristaltic pump water way, by single-chip microcomputer control work. Based on user needs collection, mixing ratio, and water mixture water.meet the state environmental protection administration released by HJT 372-2007 "Water quality automatic sampler technical requirements and test methods" code for sampling requirements. BC-9600 using standard 12 V battery work, work in the enough power to use alternative to the car battery. (should be equipped with special cable) matching flow sensor, and flow measurement, and the measured data and sampling flow condition and storage, storage contents off electricity not lost, afterwards the inspection. Environmental monitoring, charge is for water pollution monitoring work and environmental protection scientific research department research work for one of the instrument.
2.Main function indicators:
1.Sample method:
* Mixed sample:some time or different times (Time control sampling).
Delay of sample:(1~9999min)for set. Increment is 1 min.
* Mixed sample:Such as proportional sampling(Flow control sampling).
Dedicated flowmeter control sample.1~9999 pulses for set. Increment is 1 pulse.
* Output flowmeter control sample
1~9999 pulses for set. Increment is 1 pulse. Output pulse should be 5V~15V positive pulse.
2. Water mixed number N: 1 ~ 200 set arbitrary.
3. Water containers (optional) : five or 10 liters polyethylene barrels.
4. Error of sampling quantity:±5%
5. Accuracy of sample retry:±5ml.
6. Vertical range:8m .
7. Horizontal range: 50m, the sample tube has auto-wash function.
8. Error of timing control:△1≤0.1% and △12≤30S.
9. Airtightness of piping system: ≤-0.05MPa.
10. Mean time between failure: ≥3000h/time.
11. Insulation resistance: >20MΩ.
12. 2.8TFT colorful liquid crystal display,it use Human-computer dialogue.
13. Software trick lock, can protect the instrument in the program not be changed.
14.Sampler could auto-record and save sampling for each time. After match with flowmeter, the record capacity is about to record half year for each data per 5 minutes. Data have 2 types: instantaneous flux and integrated flux. Each data conclude: mouth, day, minute. Each flux data group of time interval could be arbitrarily set. New data will replace old data when no space. Instantaneously cut power source can’t miss data. User could use these data and sample test results to analysis.