Brief Introduction
Single unit acrylic acid elastic waterproof coating is a emulsified coating with the key material imported from abroad and mixing with the good adjuvant and filler. It contains no poison, taste and pollution, which can be used directly on the wet or dry bricks, mortar, concrete, metal, rubber, plasterboard and other bases. Also it can be used as the indoor or outdoor paints or binders.
Features
1.Can be used in wet area directly.
2.No poison, no taste, no pollution, simple operation.
3.Excellent resistance to crack, water, aging, changeable weather.
4.Can be made into different colors according to client’s requirements.
Application procedure:
1.The base shall be clean before application, keeping no loosing and water on the leveling layer , shall stir in the barrel when gatherring every time to avoid precipitation, if there is precipitation, shall be mixed prior to application.
2.Brush with roller or brusher.
3. After application
Cautions:
1.The waterproof layer shall be brushed twice according to requirements of Acrylic Waterproof Coating.
2.Coating to be as even as possible, without local precipitation; and shall brush twice to keep the coating and base to be stick firmly, without bubbles.
3.Drying time of coating has relatioship with construction site temperature,humidity,ventilation condition, thy drying time will be long if there is low temperature,very humidity and poor ventilation in construction site, instead, the drying time will be shorter.
4.The amount of coating must be in accordance with the provisions of reclaming, can not be too thick or too thin.
Data sheet
Guangdong Province Contruction Products Inspection Center
Test Report
Sample name:DY-Acylic Waterproof Coating
Ref No:GD2011-01-00137
Specifation/modle: DY-PEW-i
Sample No:011-01-00137
Ref Standards:JC/T864-2008
Sample quanity: 3kg
No.
Test Item
Standard value
Measured value
1
Solid content,%
≥65
76
2
Tensile strength, Mpa
≥1.0
1.2
3
Elongation,%
≥300
357
4
Cold flexibility
-10°C, no cracks
No cracks
5
Watertightness, (0.3Mpa, 30min)
No leakage
Pass
Conclusion
All test are qualited based on the Ref Standards:JC/T864-2000 's conventional items and instruction .